Alarm |
Alarm Sub Type |
Alarm Description (Hover) |
|
Amplifier Communications |
Channel Number |
The amplifier network module has failed to communicate with the specified amplifier output module |
|
Amplifier Configuration |
Channel Number |
The amplifier output channel is not correctly configured |
|
Amplifier PSU |
|
The amplifier output module power supply has failed |
|
Amplifier PSU Overload |
|
A fault occurred on the amplifier power supply |
|
Audio Input Path |
Channel Number |
The device is configuring and cannot deliver audio at this time |
|
Audio Output Path |
Channel Number |
The audio output path has failed |
|
Auxiliary PSU Failure |
PSU Number |
A fault occurred on the auxiliary 24V power supply |
|
Brown Out |
Channel Number |
The amplifier output module power supply has fallen below operational voltage |
|
Channel Failure |
Channel Number |
The amplifier output channel has failed |
|
Control Alarm Input |
Channel Number |
A Control Input configured to report an alarm is active |
|
Control Input Communications |
|
The host processor cannot communicate with the specified Control Input |
|
Control Input Open |
Channel Number |
The control input is open circuit |
|
Control Input Short |
Channel Number |
The control input is shorted to ground |
|
Control Output Communications |
|
The host processor cannot communicate with the specified control output |
|
Control Output Open |
Channel Number |
The control output is open circuit |
|
Control Output Short |
Channel Number |
The control output is shorted to ground |
|
DC Out |
Channel Number |
DC Voltage has been detected on the output channel |
|
DSP Operation |
|
The device has a digital signal processor fault that may prevent delivery of audio |
|
Fan Stuck Rotor |
Fan Number |
The chassis fan has failed |
|
Flash Memory |
|
A hardware memory corruption has been detected |
|
Ground Fault |
Channel Number |
A cable short to ground was detected on the output channel |
|
Heap Memory |
|
The device's heap memory has been exhausted |
|
IM-16 Input |
|
The IM-16 input has a fault |
|
IM-16 Input Transmission Path |
The IM-16 Control Input configured to indicate a path fault has been asserted |
|
|
LSI-16 Network |
1 |
The LSI-16 or monitored equipment has a network Fault |
|
Main PSU Failure |
|
A fault occurred on the AC power supply |
|
Microphone |
|
The microphone has failed |
|
Network Interface |
Interface Number |
The network interface has failed |
|
Output Communications |
|
The LSI-16 is unable to communicate with its control output driver |
|
Output Driver Overload |
Channel Number |
A clip fault occurred at the amplifier output |
|
Output Open Short Low |
Channel Number |
The control output is shorted to ground |
|
Output SDRAM |
|
There is a fault in the audio delay memory |
|
Output Short High |
|
The control output is connected to an unexpected voltage source |
|
Plug-in Module Installed |
Module Name |
There is a fault with the option module or hardware is inconsistent with the device's configuration |
|
Power Over Ethernet |
|
The power supply from the Power over Ethernet (PoE) source has failed |
|
Remote Configuration |
|
A remote device in the emergency system is not configured |
|
Remote General |
|
A configured emergency device has a fault |
|
Remote Memory |
|
A configured emergency device has a memory fault |
|
Remote Network |
|
A configured emergency device has a network fault |
|
Remote Power Supply |
|
A remote emergency device has a power supply fault |
|
RS-232 Interface Transmission Path |
|
An LSI-16 VTP handshake token was not received in the required time on the LSI-16 serial port |
|
Secondary Active |
|
The back-up amplifier in a redundant pair is now active |
|
Short Circuit |
Channel Number |
The amplifier has detected a short circuit on the output channel |
|
Speaker Line |
Channel Number |
The output channel has a speaker line fault |
|
Stack Memory |
|
The device's stack memory has been exhausted |
|
System Power |
|
A fault with the primary DC power supply to the LSI-16 has been detected |
|
System Power Transmission Path |
|
The LSI-16 is indicating a system power transmission path. Check IM-16 Control Input 1 or if fitted CI-1 U, P, W Connections |
|
TCP/IP Interface Transmission Path |
|
An LSI-16 VTP handshake token was not received in the required time on the TCP/IP control port |
|
Thermal |
Channel Number |
The amplifier output channel has been shutdown due to overheating |
|
TTS Request Service |
|
The TTS's request manager is not running |
|
TTS-1(e) Voice Configuration |
|
The TTS-1(e)'s configuration is using a Voice Font that has not been installed on the TTS-1(e) |
|
Virtual Input Transmission Path |
|
A virtual input configured to indicate a path fault has been asserted |